Slideshow Image 0 Slideshow Image 0 Slideshow Image 0 Slideshow Image 0 Slideshow Image 0 Slideshow Image 0 Slideshow Image 0 Slideshow Image 0 Slideshow Image 0 Slideshow Image 0 Slideshow Image 0 Slideshow Image 0 Slideshow Image 0

INTELIGENT ENERGY SAVING

Don't forget your alt text

IES - Intelligent Energy Saving is the management algorithm of efficient power, the completion of an advanced regulation system, that when applied to the control…

continua

PROBLEM SOLVED

Don't forget your alt text

What is a problem for the customer, is an opportunity for SELPRO. The collection of customer issues resolved by SELPRO products.

continua

CLIMA-SINERGY

Don't forget your alt text

Designed to interact with SELPRO regulators and ventilation systems, the software collects operating parameters and then analyses and modifies them to optimise system performance during…

continua

Print

RDM300

Low cost Master & Slave three-phase controller

Don't forget your alt text

Areas of use

Used in HVAC&R plants to control and regulate:
  • ventilation, suction
  • destratificators
  • temperature (dry-cooler, heaters)
  • pressure (ventilated heaters like condensers, evaporators)
  • differential air flow (laminated flow plants, suction hoods)

Don't forget your alt text

What's

RDM300 device is a multifunction digital unit with 2+1 transducer inputs, to regulate the speed of three-phase AC Motors used in axial or centrifugal fans. Designed using a "state of art" microcontroller, is suited to have a choice of 14 different default software configurations ready for ventilated heat exchanger applications. It is optimized with “IES”, the innovative control algorithm for HVAC&R applications.

Don't forget your alt text

Driving Mode

Master Unit - automatic regulator:
two different modes are selectable:
  • PID with "IES" technology to keep at Set Point the selected transducer value (i.e. temperature, pressure)
  • P (proportional)to keep inside Proportional Band the selected transducer value (i.e. temperature, pressure).
Driving command is selectable direct (DIR) or reverse (REV).

Slave Unit - repeater driver:
the driving command is directly related to the input command value, still selectable are direct (DIR) or reverse (REV) modes.

Dati RDM300

Three-Phase AC Power Supply 230Vac ±10%
400Vac ±20% (Range esteso std)
480Vac ±10%
other voltages on request
 
Nominal Current (RMS) at 50°C 8A
12A
20A
28A
30A
 
Frequency 50/60Hz aut. sel.
 
Driving Command continues 0...100%
 
Motor Connection 1
2
4
8
 
Control Technology digital
 
Motor control type phase cutting
 
Case IP Grade IP55
IP00
IP20
 
Conforms to the following standards Standard EN 61800-3 (directive 2004/108 CE)
Standard EN 50178 (directive 2006/95 CE)
Standard EN 60204-1 (directive 2006/95 CE)
Connectable into IT-TT-TN systems
 
Display and settings LCD display with backlight; 2 lines of 16 characters with programming keyboard
programming dip switches
signaling leds
system reset
 
Control Function PID master, IES technology
proportional master (P)
slave (power unit)
 
Number of working parameter set 1
 
Control Parameters PID parameters
set-point
proportional band
minimum speed limit
cut-off
maximum speed limit
maximum night speed limit
acceleration / deceleration slope (starter)
motor phase V/I displacement correction (cosφ)
 
Special Features direct / reverse mode selection
bypass driving Resonances
Alarm Relè Programming
ON/OFF digital inputs programming
set-point position selection (min./max RPM)
maximum speed Limit bypass (over speed)
minimum speed limit bypass (cut-off)
safe mode to protect programming parameters
automatic reset
restore default parameters
 
Serial Connections not available
 
commands analog input 2 + 1 PWM Slave
 
Analog input type 0-20mA
4-20mA
0-10Vdc
NTC 10KOhm 25°C
unpolarized PWM 3-30V; maximum frequency 120Hz
 
Transducer type 0...15bar
0...25bar
0...30bar
0...45bar
0...50bar
-20°C...+90°C
0...20mA
0...10Vdc
PWM%
 
ON/OFF inputs number 2
 
Logic inputs working modes (S2) remote start/stop
(TK) thermal contact or electric panel alarm
 
Auxiliary power supply 5,0 Volt (Vrr) stabilized
10,0 Volt (Vrr) stabilized
20-24 Volt ±10%
 
0-10Vdc programmable analog outputs 1
 
Relays outputs 1
 
Relays programmable outputs 1
 
Protections power supply overvoltages
maximum internal temperature
minimum level power supply
phase loss detection
transient suppressors on analog signal
transient suppressors on logic inputs
probe failure
input lines insulated from power supply voltage
 
Work temperature -10°C...+50°C
 
Storage temperature -20°C...+80°C